Fluorene fluorenone. 9H 2019-01-07

Fluorene fluorenone Rating: 6,7/10 1369 reviews

FLUORENE

fluorene fluorenone

Acetone a ketone can be used. Relationships between chromatographic retention and thermal reactivity, J. The retention factor, or Rf, is defined as the distance traveled by the compound divided by the distance traveled by the solvent. Conversely, if you know the structures of the compounds in a mixture, you can predict that a low polarity compound will have a larger Rf value than a polar compound. The stationary phase is a powdered adsorbent which is placed in a vertical glass column.

Next

Fluorene

fluorene fluorenone

The polarities of both mixture component and solvent used as mobile phase are determining factors in how fast compound travels Mix polar and nonpolar solvent. If I had done the procedure in a better way, the separation between the two compounds would have been purer and my retention factors would have changed. They can react exothermically with bases and with diazo compounds. The mixture to be analysed is loaded on top of this column. For the liquid liq , transfer 1 or 2 drops to a push-top vial. Molecular polarity is dependent on the difference in electronegativity between atoms in a compound and asymmetry of the compound's structure. Health, 44 5 , 1998, 334-351.

Next

Lab 4 Thin Layer and Column Chromatography Flashcards

fluorene fluorenone

Flush victim's eyes with water or normal saline solution for 20 to 30 minutes while simultaneously calling a hospital or poison control center. Discussion: By analyzing how strongly the two compounds were attracted to the stationary phase of the silica gel in the column, we can understand why the compounds moved down the column at the rate that they did. The solvent flows down the column, causing the components of the mixture to distribute between the powdered adsorbent and the solvent, thus hopefully separating the components of the mixture so that as the solvent flows out of the bottom of the column, some components elute with early collections and other components elute with late fractions. All firefighters should wear full-body protective clothing and use self-contained breathing apparatuses. Because of toxicity, cost, and flammability concerns, the common solvents are hexanes or petroleum ethers, ligroin and ethyl acetate an ester.

Next

Lab 4 Thin Layer and Column Chromatography Flashcards

fluorene fluorenone

Solvent wash all contaminated surfaces with acetone followed by washing with a strong soap and water solution. Alcohols methanol, ethanol can be used. Use absorbent paper dampened with acetone to pick up any remaining material. In principle, the chemical compound that flows through the column at a faster speed is more non-polar; therefore, in this case fluorene was more non-polar than 9-fluorenone. The basic principle of chromatography is to separate certain compounds based on their structure, ability to hydrogen bond and polarity between the stationary phase and mobile phase.

Next

9H

fluorene fluorenone

Be prepared to transport the victim to a hospital if advised by a physician. Because 9-fluorenone was held tighter in the silica gel beads in the column, it did not go down the column as fast as fluorene did. . Seal your contaminated clothing and the adsorbent paper in a vapor-tight plastic bag for eventual disposal. Analysis of carcinogenic components in neutral nonpolar fractions, Nippon Kagaku Kaishi, 3, 1988, 311-320. Following this, 4 elutions were collected in test tubes as hexane was continuously being added to the column. Critical evaluation and additional indices, J.


Next

FLUORENE

fluorene fluorenone

Gas chromatographic-mass spectrometric studies of reactions of tricyclic aromatic hydrocarbons with hypochlorite in dilute aqueous solution, J. There are different types of chromatography devices used and various techniques of separation that are applied to separate chemical mixtures. The plate showed that fluorene moved up the plate at a higher level than 9-fluorenone. The solvent system with a mixture between acetone and hexane allowed the yellow band to be eluted off the column because polar solvents such as acetone are helpful in moving chemical compounds down the column that tend to have a higher polarity, such as 9-fluorenone. The retention factor was then calculated.

Next

9H

fluorene fluorenone

For the solids sol , transfer a spatula tip of each material to a vial one vial per sample! The include common identification numbers, the , U. Techn iques in Organic Chemistry. You should extinguish any fires involving this chemical with a dry chemical, carbon dioxide, foam, or halon extinguisher. A good spotting solvent is ethyl acetate: it dissolves most substances that we use in lab, evaporates readily and does not react with the substances under study. Do not reenter the contaminate area until the Safety Officer or other responsible person has verified that the area has been properly cleaned.

Next

9H

fluorene fluorenone

The plate is placed in a reservoir of solvent so that only the bottom of the plate is submerged. Do not put any ointments, oils, or medication in the victim's eyes without specific instructions from a physician. Diethyl ether can be used, but it is very flammable and volatile. Department of Homeland Security's Chemical Facility Anti-Terrorism Standards, and the U. The stationary phase is a powdered adsorbent which is fixed to a aluminum, glass, or plastic plate. However, if this chemical makes direct contact with your gloves, or if a tear, puncture or hole develops, remove them at once. Gently wash all affected skin areas thoroughly with soap and water.

Next

Column Chromatography and TLC Lab Analysis

fluorene fluorenone

For this difference, the oxygen that sticks out from 9-fluorenone was able to hydrogen bond to the silica gel beads which allowed it to be held tighter in the column than fluorene. Department of Transportation hazard labels, and a general description of the chemical. The retention factors were calculated to find the distances the samples of the compounds being tested moved up the plate relative to the distances moved by the solvent front. Add solvent to dissolve the sample - the height of solvent in the vial should be about 1 cm. Quantification of mutagenes and other organic compounds.

Next

Fluorene

fluorene fluorenone

It moves through the chromatography column the stationary phase where the sample interacts with the stationary phase and is separated. This compound is not very flammable but any fire involving this compound may produce dangerous vapors. Structurally, fluorene does not have a carbonyl functional group and 9-fluorenone does. Here, we present data from using Column Chromatography and Thin-Layer Chromatography to separate fluorene from 9-fluoreneone and to determine the best solvent mixture for a separation. A, 1108 2 , 2006, 279-284. Provide proper respiratory protection to rescuers entering an unknown atmosphere.

Next